[Oral Presentation]Optimized canopy air curtain dust protection using a two-level manifold and computational fluid dynamics
00
days
00
hours
00
minutes
00
seconds
00
days
00
hours
00
minutes
00
seconds

[Oral Presentation]Optimized canopy air curtain dust protection using a two-level manifold and computational fluid dynamics

Optimized canopy air curtain dust protection using a two-level manifold and computational fluid dynamics
ID:507 View Protection:ATTENDEE Updated Time:2024-05-20 09:04:18 Hits:533 Oral Presentation

Start Time:Pending (Asia/Shanghai)

Duration:Pending

Session:[No Session] » [No Session Block]

No files

Abstract
Prolonged exposure to high concentrations of respirable coal mine dust causes coal workers’ pneumoconiosis and silicosis. Underground coal mine roof bolter operators are more prone to elevated exposure to coal and silica dust. The canopy air curtain (CAC) was developed by NIOSH to protect roof bolter operators from the exposure. The CAC supplies filtered air over the breathing zone of the operator. This dilutes the high coal dust concentrations and provides for an impenetrable air curtain. Many studies have been carried out to improve CAC efficiency. However, field test has shown variable dust control efficiencies indicating rooms to further improve due to the non-uniform airflow distribution across the plenum and ineffective perimeter flow. This study therefore redesigns the CAC with optimized flow distribution that effectively protects roof bolters from coal dust exposures. The Simplex Evolutionary Operational (EVOP) optimization algorithm was applied to optimize the configuration of the new CAC. Computational fluid dynamics (CFD) simulations are run at each iteration of the algorithm. The combination of these methodologies led to the optimization of the uniformity of airflow distribution across the plenum to achieve the best possible uniformity. A lab experiment using a physical model of the optimized CAC was used to validate the CFD model and confirm the ability of this design to protect roof bolter operators from excessive coal dust.
 
Keywords
Speaker
光/Xu Guang 徐
教授 密苏里科学技术大学/Missouri University of Science and Technology

Comment submit
Verification code Change another
All comments

Contact us

Abstract and Paper:Ms. Zhang
Tel:(0086)-516-83995113
General Affairs:Ms. Zhang
Tel:(0086)-516-83590258
Hotel Services:Ms. ZHANG
Tel:15852197548
Sponsorship and Exhibition:Mr. Li
Tel:(0086)-516-83590246
Log in Registration Submit Abstract Hotel