[Oral Presentation]Rapid Detection of Crystalline Silica Content in Mine Dust by Direct-on-Filter Method Based on Infrared Spectroscopy
00
days
00
hours
00
minutes
00
seconds
00
days
00
hours
00
minutes
00
seconds

[Oral Presentation]Rapid Detection of Crystalline Silica Content in Mine Dust by Direct-on-Filter Method Based on Infrared Spectroscopy

Rapid Detection of Crystalline Silica Content in Mine Dust by Direct-on-Filter Method Based on Infrared Spectroscopy
ID:190 Submission ID:271 View Protection:ATTENDEE Updated Time:2024-05-19 11:22:30 Hits:565 Oral Presentation

Start Time:2024-05-30 20:20 (Asia/Shanghai)

Duration:10min

Session:[S2] Safety Engineering and Occupational Health » [S2-5A] Evening of May 30th-5A

No files

Abstract
With the increasing degree of mine mechanization, the concentration of dust produced by mining operation also increases. The long-term exposure of workers to the mine environment containing crystalline silica will lead to the occurrence of silicosis, and the rate and degree of silicosis are closely related to the content of crystalline silica in mine dust. To improve the accuracy and efficiency of detecting crystalline silica in mine working environments, the direct-on-filter (DoF) method based on infrared spectroscopy (IR) was studied, eliminating the sample preparation step: ashing the sample filter. This study utilized three types of mine dust samples: coal dust, coal gangue dust, and metal mine dust. According to the mass of crystalline silica contained in the samples and its infrared spectral intensity data, unary linear regression (ULR) and partial least square regression (PLSR) models were established. Compared to the ULR model of mine dust samples, the PLSR model exhibits a better fitting effect, with a determination coefficient (R2) exceeding 0.98 and a root mean square error (RMSE) below 0.35μg. Among these models, the PLSR model applied to metal dust samples exhibited the best fit, with an R2 as high as 0.9996 and an RMSE as low as 0.05μg. The results indicate that the DoF method based on IR is in good agreement with the established standard method, validating its reliability for accurately analyzing the crystalline silica content in mine dust.
Keywords
crystalline silica, infrared spectroscopy, direct-on-filter, unary linear regression, partial least square regression
Speaker
Yingshuo Zhu
China University of Mining and Technology

Submission Author
颖硕 朱 中国矿业大学
丽娜 郑 中国矿业大学
Wenting Feng China University of Mining and Technology
Comment submit
Verification code Change another
All comments

Contact us

Abstract and Paper:Ms. Zhang
Tel:(0086)-516-83995113
General Affairs:Ms. Zhang
Tel:(0086)-516-83590258
Hotel Services:Ms. ZHANG
Tel:15852197548
Sponsorship and Exhibition:Mr. Li
Tel:(0086)-516-83590246
Log in Registration Submit Abstract Hotel