[口头报告]Performance evaluation of low-concentration methane combustion in a four-layer gradually-varied porous burner
00
days
00
hours
00
minutes
00
seconds
00
days
00
hours
00
minutes
00
seconds

[口头报告]Performance evaluation of low-concentration methane combustion in a four-layer gradually-varied porous burner

Performance evaluation of low-concentration methane combustion in a four-layer gradually-varied porous burner
编号:365 访问权限:仅限参会人 更新:2024-05-15 19:33:58 浏览:510次 口头报告

报告开始:2024年05月30日 15:10 (Asia/Shanghai)

报告时间:20min

所在会议:[S5] Smart Energy and Clean Power Technology » [S5-1] Afternoon of May 30th

暂无文件

摘要
Porous media combustion (PMC) has made a comeback as a practical technology for the utilization of low-concentration methane (LCM) from coal mining. However, the conventional direct-fired PM burner still suffers from the rampart of flame stability and combustion efficiency not addressing industrial demands. Herein, a four-layer gradually-varied porous burner was innovatively developed for LCM combustion to investigate combustion performance under lean combustion conditions (CH4 volume fraction below 5 %). The methane conversion, pollutant emissions, and flue gas temperature were also evaluated in detail. The results indicated that the burner offered a favorable combustion resistance due to the gradually-varied PM arrangement to heighten combustion stability with subtle temperature fluctuation and flame migration. The flammability limit of LCM was extended to the lowest equivalence ratio of 0.43 with stationary combustion at 240 °C for 120 min. The energy efficiencies of the LCM combustion under lean combustion conditions were greatly boosted with the highest combustion and thermal efficiencies attained at 99.52 % and 70.05 %, respectively. The maximum 99.93 % CH4 conversion was acquired at an equivalence ratio of 0.45 and a flow rate of 80 L/min. LCM combustion in the burner achieved extremely low pollutant emission levels and the overall CO and NOx emissions were 58.04 ppm and below 23 ppm respectively under the experimental conditions. In addition, the high-quality flue gas with an average temperature of more than 516 °C was detected in the operating process, which allowed the available heat utilization at the coal mine scenes or in other industries.
关键字
low-concentration methane,porous media combustion,combustion performance,energy efficiencies,heat utilization
报告人
Yunqi Cao
China University of Mining and Technology

发表评论
验证码 看不清楚,更换一张
全部评论

联系我们

投稿事宜:张老师
电话:0516-83995113
会务事宜:张老师
电话:0516-83590258
酒店事宜:张老师
电话:15852197548
会展合作:李老师
电话:0516-83590246
登录 注册缴费 提交摘要 酒店预订